PeptMentor
CalculatorsHow we source
PeptMentor
PeptMentor
Peptides
Eloralintide
Retatrutide
GHK-Cu
Pinealon
KPV
KLOW
All peptides
Compared
Eloralintide vs cagrilintide
Eloralintide vs retatrutide
Retatrutide vs tirzepatide
Guides and tools
Bac water for peptides
How to reconstitute peptides
Peptide reconstitution calculator
All guides
About
How we source
About
Editorial policy
Open the peptide calculator
PeptMentor

Plain answers about peptides and GLP-1 medicines. Every figure links to its source and says what kind of study it came from.

No dose advice. No sponsors, sellers or affiliate codes.

Peptides

  • Eloralintide
  • GHK-Cu
  • KLOW
  • KPV
  • Pinealon
  • Retatrutide
  • All peptides

Compare

  • Eloralintide vs cagrilintide
  • Eloralintide vs retatrutide
  • Retatrutide vs tirzepatide

Guides and tools

  • Peptide reconstitution calculator
  • Bac water for peptides
  • How to reconstitute peptides
  • All guides

About us

  • About
  • How we check facts
  • Editorial policy
  • Sources
  • Contact
© 2026 PeptMentor LLC. For information only, not medical advice. In an emergency call 911.
Medical disclaimerTermsPrivacyConsumer health data
  1. /Home
  2. /Calculators
  3. /Peptide reconstitution calculator
Calculator

Peptide reconstitution calculator

Enter the mg on your vial label and the water added to get concentration. Then enter the amount from your prescription or label to get mL and U-100 syringe units; no amount is filled in for you.

Use the peptide calculator

Arithmetic only
The amount field starts empty. Use the number on your own prescription or product label. This page does not say what amount to use or whether an injection is safe for you.

Emergency: call 911 (or your local emergency number). Possible overdose or wrong amount: Poison Help, 1-800-222-1222, free and open 24 hours. Report a bad reaction to the FDA through MedWatch.

Before you use the calculator

  • It does arithmetic on the numbers you type from your own label. It does not suggest an amount or say whether anything is safe for you.
  • It is not medical advice. Check every result with your pharmacist or prescriber before you use it.
  • Its units are for U-100 insulin syringes only (the box or barrel says U-100).
  • In an emergency call 911. For a possible overdose call Poison Help at 1-800-222-1222.

Your answer is saved only in this browser so you are not asked again. See the privacy policy.

Preset buttons are common vial label sizes in mg, not doses.

StepFormula
Concentrationmg in the vial ÷ mL of water
Volumeyour amount ÷ concentration
U-100 syringe unitsvolume in mL × 100

Enter your amount in mg. If your label gives mcg, divide by 1,000 first (1 mg = 1,000 mcg).

Facts checked 2026-11-18 · by PeptMentor Team · How we source

Worked example

These numbers are a vial size and syringe marks
They show how to read a syringe. They are not a dose.
  1. Concentration

    A 10 mg vial mixed with 2 mL of water holds 10 ÷ 2 = 5 mg per mL.

  2. What each syringe mark holds

    On a U-100 syringe, 100 units = 1 mL, so 10 units = 0.1 mL. At 5 mg/mL, 0.1 mL holds 5 × 0.1 = 0.5 mg, and 1 unit holds 0.05 mg (50 mcg).

  3. From your amount to units

    Units = (your amount in mg ÷ concentration in mg/mL) × 100. Put in the amount from your own prescription or label. If the result is below 1 unit or above the syringe capacity, check whether mg and mcg were mixed up.

How the calculator works

This peptide reconstitution calculator uses the same three formulas you would use on paper. Adding water never changes how many milligrams are in the vial. It only changes how many milligrams sit in each millilitre.

What you wantFormulaUnit
Concentrationmg in vial ÷ mL of watermg/mL
Volume to drawyour amount (mg) ÷ concentrationmL
U-100 syringe unitsvolume (mL) × 100units

The three formulas

Why U-100 units are volume, not drug amount. "U-100" comes from insulin: U-100 insulin contains 100 units per mL, and its label says to use only a U-100 syringe[1]. The marks on that syringe are therefore 1/100 of a mL each. When you draw any other solution with it, a "unit" mark tells you volume only. How much peptide that volume holds depends on the concentration you mixed.

Syringe size. A syringe can only be read as finely as the marks printed on its barrel, so check the scale on your own syringe. A 0.3 mL U-100 syringe holds 30 units, a 0.5 mL holds 50 and a 1 mL holds 100: the units per mL stay the same, only the capacity changes.

Common vial and water combinations

This peptide conversion table is pure arithmetic: vial size ÷ water = concentration, and 10 units on a U-100 syringe = 0.1 mL. It is a table for reading syringe marks, not a table of amounts to use.

Vial size1 mL water2 mL water3 mL water
5 mg5 mg/mL · 0.5 mg per 10 units2.5 mg/mL · 0.25 mg per 10 units1.67 mg/mL · 0.17 mg per 10 units
10 mg10 mg/mL · 1 mg per 10 units5 mg/mL · 0.5 mg per 10 units3.33 mg/mL · 0.33 mg per 10 units
20 mg20 mg/mL · 2 mg per 10 units10 mg/mL · 1 mg per 10 units6.67 mg/mL · 0.67 mg per 10 units
30 mg30 mg/mL · 3 mg per 10 units15 mg/mL · 1.5 mg per 10 units10 mg/mL · 1 mg per 10 units

Each cell: concentration, then mg held in 10 units (0.1 mL). Values rounded to 2 decimals.

Unit conversions on this page

mL to units. On a U-100 syringe, units = mL × 100. So 0.5 mL = 50 units, 0.25 mL = 25 units and 0.1 mL = 10 units. This holds for any liquid, because the marks measure volume.

mcg to units (for example 200 mcg or 500 mcg). There is no single answer: it depends on the concentration in your vial. First convert mcg to mg (divide by 1,000), then use units = (mg ÷ mg/mL) × 100. The table below shows how much one mark holds at a few concentrations, so you can check your own result.

ConcentrationIn 1 unitIn 10 units
1 mg/mL10 mcg100 mcg
2 mg/mL20 mcg200 mcg
2.5 mg/mL25 mcg250 mcg
5 mg/mL50 mcg500 mcg
10 mg/mL100 mcg1,000 mcg

Amount held per syringe mark at a given concentration (arithmetic: 1 unit = 0.01 mL).

mg to mL. mL = mg ÷ concentration in mg/mL. ng/mL to mg/mL. 1 mg = 1,000 mcg = 1,000,000 ng, so 1 mg/mL = 1,000,000 ng/mL, and 1 ng/mL = 0.000001 mg/mL.

Common unit mistakes

  • mg vs mcg. FDA warns that "mcg" can be mistaken for "mg", and that a missing leading zero (".5 mg") can be read as "5 mg"[2]. Typing mcg into an mg field makes the answer 1,000 times too large.
  • U-100 vs U-40 syringes. Some insulins are 40 units per mL and are labelled for U-40 syringes only; one FDA-approved label states that using any other syringe "will result in incorrect dosing"[3]. On a U-40 syringe each mark is 1/40 mL, so 10 marks are 0.25 mL, 2.5 times the 0.1 mL of 10 marks on a U-100 syringe. This calculator assumes U-100.
  • Units vs IU. The "units" on a syringe barrel are volume marks. An International Unit (IU) is a measure of biological activity, a different thing (see the FAQ).
  • Wrong water volume. If you add a different amount of water than you enter, the concentration and every later step are off by the same ratio.

What this calculator does not do

Arithmetic, nothing more
It does not suggest or preset any amount, and it does not judge whether an injection is safe. Your amount comes from your prescription or product label. Our rules are in the editorial policy. Compound pages list published trial doses with their sources: see all peptides.
How to reconstitute peptides →The mixing steps, from an FDA-approved instructions for use.
Bac water for peptides →What the bacteriostatic water label says.
Methodology →How we source and check figures.

Calculator changes

Every change to how the calculator works is listed here with its date. The formulas are checked by automated tests before each release.

DateChange
2026-11-17First release: concentration, volume, U-100 units and units back to amount.
2026-11-18Math moved to a tested module; working shown step by step; warnings for results under 2 units, over the syringe, or a likely mg/mcg mix-up.

Calculator questions

Direct answers to what people search for. Bracketed numbers point to the sources at the end; the sections above have the detail.

Can you convert mcg to IU?

Not with a general formula. An International Unit is a value WHO assigns to a reference preparation of a specific substance[4], so a mcg-to-IU factor only exists where a product label states one. The "units" on a U-100 syringe are volume marks, not IU.

How many units is 1 mL?

On a U-100 syringe, 1 mL = 100 units, so 0.5 mL = 50 units and 0.1 mL = 10 units. On a U-40 syringe, 1 mL = 40 units.

Does more water change the amount of peptide?

No. The milligrams in the vial stay the same. More water lowers the concentration, so the same amount takes up more units on the syringe.

Why does another calculator give a different answer?

Usually because of rounding, a mcg value entered as mg, or a syringe that is not U-100. Re-run the three formulas on this page by hand to see which step differs.

Which syringe size should the calculator use?

The math is the same for 0.3 mL, 0.5 mL and 1 mL U-100 syringes: 100 units per mL. Only the capacity differs (30, 50 or 100 units), so check the result fits the syringe you have.

Is my data saved?

No. The calculator runs in your browser and does not send or store what you type.

Sources

  1. 1.Humulin R U-100 prescribing information and carton (FDA-approved label, revised 6/2023) Approved label
  2. 2.FDA: A Microgram of Prevention Is Worth a Milligram of Cure (updated 05/21/2024) Regulator
  3. 3.ProZinc 40 IU/mL package insert (FDA-approved animal drug label, FDA-hosted) Approved label
  4. 4.WHO: Providing international biological reference standards Regulator
On this pageUse the peptide calculatorWorked exampleHow the calculator worksCommon vial and water combinationsUnit conversions on this pageCommon unit mistakesWhat this calculator does not doCalculator changesCalculator questionsSources